Vulnerabilities and exploitation

Node2Shell: Siemens names SCADA and building management products affected by Brotli flaw

Siemens advisories SSA-242944 and SSA-045512 list SIMATIC WinCC, COMOS, Desigo CC and grid software affected by CVE-2026-111497, a critical Brotli decoder bug CISA lists as exploited.

By Junglewise News DeskPublished 5 min read
A stone sign reading "SIEMENS" outside the glass facade of the company's Munich headquarters building.
Álvaro de la Paz Franco, public domain via Wikimedia Commons

Siemens has published two detailed advisories naming the industrial, building management and power grid products affected by a critical flaw in the Brotli decoder, the compression library bundled into Node.js, Python packages and the .NET runtime. The bug, tracked as CVE-2026-111497 and nicknamed Node2Shell (Siemens also calls it Broccoli2Shell), lets a remote attacker who is not logged in send a specially crafted compressed stream and corrupt memory, leak data, crash the application or potentially run code.

That matters more than a typical library bug because the affected products sit at the operating layer of factories, buildings and electricity networks: SCADA systems, a plant engineering platform, a building management suite and grid analysis software. For several of them, including SIMATIC WinCC V7/V8, SIMATIC WinCC Runtime Professional, COMOS Walkinside and the User Management Component, Siemens says no fix is available yet and offers mitigations instead. The Cybersecurity and Infrastructure Security Agency (CISA) added the flaw to its Known Exploited Vulnerabilities Catalog on 27 October 2026 based on evidence of active exploitation.

What to do now

  1. Treat this as exploited. CISA added CVE-2026-111497 to the KEV Catalog based on evidence of active exploitation. Binding Operational Directive 26-04 requires federal civilian agencies to remediate high-risk KEV entries quickly, and CISA encourages every organisation to prioritise KEV vulnerabilities the same way.
  2. Patch the underlying runtimes first. Update the Brotli C library to 1.0.10, 1.1.1 or 1.2.1; Node.js to v22.23.4, v24.22.1 or v26.12.1; Python Brotli to 1.2.1 and brotlicffi to 1.2.1.0. If you are running Node.js 25, 23, 20 or older, there is no fix for those branches: Siemens recommends moving to 22, 24 or 26.
  3. Apply the .NET updates where products depend on them. For Desigo CC V8 and V9, Integrated PA Suite Tester and SENTRON Powermanager V8 and V9, Siemens points to installing the latest .NET security updates through Windows Update.
  4. Update the products that have fixes. SIMATIC BRAUMAT and SIMATIC SISTAR to V8.2 Update 5 or later; SIMATIC WinCC Open Architecture V3.20 to V3.20 P17.1 or later; Gridscale X DSA to V5.4 or later; Gridscale X PSS/E to V36.8.0 or later.
  5. Where no fix exists, turn Brotli off. Siemens advises switching off Brotli compression and decompression temporarily, either in the application or at a proxy in front of it, wherever the feature is not genuinely needed. For TIA Administrator and the User Management Component with UMC authentication enabled, Siemens describes an Internet Information Services (IIS) Request Filtering rule: "Scan Headers "Content-Encoding" and Deny Strings "br".
  6. Check whether you are actually exposed. For Siemens Industrial Edge, CISA notes that no action is required when no Management Applications are installed on Industrial Edge Management, because the vulnerable library ships in the stack but the affected functionality is neither used nor exposed. Siemens reaches similar conclusions for several KACO blueplanet inverter lines, Heliox EV chargers, SICHARGE FLEX and UC, Sifinity Go and Setup, the VersiCharge AC Series and VersiCloud, either because no external input reaches the vulnerable function or because Node.js is not present at all.
  7. If you operate critical power systems, Siemens recommends that transmission and distribution system operators verify that resilient, redundant secondary protection measures are in place so a cyber incident does not become a grid reliability problem.

Technical details

CVE-2026-111497 is an out-of-bounds write in the Brotli decoder maintained by Google, affecting versions 1.0.3 through 1.2.0. CISA's KEV entry describes it as an unchecked return value issue that lets a remote, unauthenticated attacker corrupt adjacent decoder state memory, disclose memory contents, cause denial of service or execute arbitrary code through a crafted Brotli-compressed stream. Siemens put it plainly in its own bulletin: "An out-of-bounds write can potentially result in a crash, a memory leak or a remote code execution".

The Node.js project shipped fixes on 21 October 2026. Siemens acknowledged the issue on 28 October, said it was evaluating the impact across its portfolio, and has since published five related advisories: SSA-898633 (Palo Alto Networks PAN-OS running on RUGGEDCOM APE1808), SSA-443410 (Industrial Edge Management Applications), SSA-045512, SSA-242944 and SSA-678870.

SSA-242944 (V1.0, 10 November 2026) covers Siemens industrial products and carries a CVSS v3.1 base score of 9.8 and a CVSS v4.0 base score of 9.2. Affected with no fix currently available: COMOS Walkinside (all versions), Project Server Web Administration Tool (all versions), SIMATIC WinCC Companion, SIMATIC WinCC Runtime Professional, SIMATIC WinCC Unified for Industrial Edge, SIMATIC WinCC Unified PC Runtime, SIMATIC WinCC Unified SIQENCE, SIMATIC WinCC V7/V8, TIA Administrator and the User Management Component. SIMATIC Profiling Tool (all versions) is affected with no fix planned. SIMATIC WinCC OA V3.21 (all versions) is affected with no fix currently available, while V3.20 is fixed in V3.20 P17.1. SIMATIC BRAUMAT and SISTAR from V8.2 Update 1 to before V8.2 Update 5 are affected. gDAP (gPROMS Digital Application Platform) is listed as not affected, because the component is not shipped with the product.

SSA-045512 (V1.3, last updated 18 November 2026, originally published 30 October 2026) covers Siemens software products with the same CVSS scores. It names Desigo CC, Gridscale X, SENTRON Powermanager, SICAM PAS CC, SICAM SCC and Integrated PA Suite Tester. SICAM PAS CC (V6.02 and later) and SICAM SCC (V7.01 and later) are affected with no fix planned, leaving the disable-Brotli mitigation as the available answer.

Separately, Microsoft published GitHub advisory GHSA-p3jp-9v83-76w9 on 25 October 2026 for CVE-2026-111497 as a .NET Brotli decoder out-of-bounds write, rated High, affecting numerous runtime and ILCompiler NuGet packages across .NET 8, 9, 10 and 11 preview. Patched versions include 8.0.33, 9.0.22, 10.0.14 and 11.0.0-rc.3.26522.148.

The reach extends well past Siemens. Amazon Web Services said it is aware of the flaw in the native Brotli decompression library, and listed affected services including Lambda, Amplify, App Runner, CodeBuild, Elastic Beanstalk, CloudWatch Synthetics and Elemental MediaLive, with some requiring customer action. Broadcom advisory VMSA-2026-0008 reports the same class of flaw in the SDDC Manager Node.js Brotli decoder, affecting VMware Cloud Foundation 9.1.x running on Google Cloud but not Google Cloud VMware Engine.

What is not yet known: whether any of the exploitation CISA cites has touched industrial systems, and when Siemens will have fixes for the products currently listed without one.