Quick answers
- Is CVE-2026-16682 exploited in the wild?
- No. Junglewise Threat Intelligence has no report of CVE-2026-16682 being exploited in the wild.
- How severe is CVE-2026-16682?
- Medium severity, with a CVSS score of 6.5, published 8 November 2026.
- Which products and versions are affected?
- IBM Power Hardware Management Console OP940.00–OP940.82; IBM Power Systems OpenBMC FW1120.00–FW1120.01, FW1110.00–FW1110.31, FW1060.00–FW1060.81, OP940.00–OP940.A2, OP910.00–OP910.95.
- Is there a fix for CVE-2026-16682?
- Yes: fixed in FW1120.02, FW1110.32, FW1060.82, OP940.A3, OP910.96, OP940.83. Until then: Restrict access to the BMC's network interface by operating it on a private network or behind a firewall to limit exposure to untrusted networks. Junglewise finds every place you run it, drafts the upgrade and applies it once you approve.
- How is CVE-2026-16682 attacked?
- It is attacked from the adjacent network, in device firmware.
- Am I affected by CVE-2026-16682?
- Check whether you run IBM Power Hardware Management Console or IBM Power Systems OpenBMC at an affected version. Junglewise does that check for you around the clock: connect your code, cloud and domains, and it matches new vulnerabilities like this one against what you actually run and tells you when one reaches you.
How to fix
- Fixed in: FW1120.02, FW1110.32, FW1060.82, OP940.A3, OP910.96, OP940.83
Restrict access to the BMC's network interface by operating it on a private network or behind a firewall to limit exposure to untrusted networks.
Technical details
The BMC's IPMI/RMCP+ network interface fails to properly initialize resources, allowing an unauthenticated remote attacker to cause a denial of service by sending crafted network traffic. The vulnerability (CWE-908: Use of Uninitialized Resource) crashes the IPMI service and places the BMC in a quiesced state. An adjacent network vector is required, though the CVSS vector indicates this is not a direct remote network attack.
Affected products
- IBM Power Systems OpenBMC FW1120.00–FW1120.01, FW1110.00–FW1110.31, FW1060.00–FW1060.81, OP940.00–OP940.A2, OP910.00–OP910.95
- IBM Power Hardware Management Console OP940.00–OP940.82
Timeline
- 2026-10-28: disclosed: Initial publication of security bulletin