# CVE-2026-118792: CompuGroup Medical default credentials in AcuXDBC

Source: https://junglewise.ai/threats/cve-2026-118792-default-credentials-permit-access-through-acuxdbc  
Publisher: Junglewise Threat Intelligence, https://junglewise.ai/threats  
Published: 2026-11-09. Updated: 2026-11-09  
License: CC BY 4.0 with a link back

CVE-2026-118792 · Severity: info · Published 2026-11-09

CompuGroup Medical software used by pharmacies and medical practices contains hardcoded default credentials in AcuXDBC that allow unauthorized administrative access. An attacker can bypass authentication and gain full access to patient and operational data without legitimate credentials, putting sensitive health information at risk.

Vendors: [CompuGroup Medical](https://junglewise.ai/threats/vendors/compugroup-medical).

## Quick answers

**Is CVE-2026-118792 exploited in the wild?** No. Junglewise Threat Intelligence has no report of CVE-2026-118792 being exploited in the wild.

**How severe is CVE-2026-118792?** Informational severity, published 9 November 2026.

**Which products and versions are affected?** CompuGroup Medical AcuXDBC.

**Is there a fix for CVE-2026-118792?** No fixed version is recorded yet. Check the vendor's advisory in the references below. If you run it, Junglewise drafts a mitigation that fits your setup and applies it once you approve, with senior security engineers behind it.

**How is CVE-2026-118792 attacked?** It is attacked over the network, in a software library.

**Am I affected by CVE-2026-118792?** Check whether you run CompuGroup Medical AcuXDBC. Junglewise does that check for you around the clock: connect your code, cloud and domains, and it matches new vulnerabilities like this one against what you actually run and tells you when one reaches you.

## Technical details

This is a hardcoded credential vulnerability (CWE-798) in AcuXDBC, a database connectivity component. An unauthenticated attacker on the network can use embedded default administrative credentials to bypass authentication and access the system. A fix has been distributed automatically to all affected installations; there is no evidence of exploitation in the wild.

## Affected products

- CompuGroup Medical AcuXDBC

## Timeline

- 2026-11-09: disclosed

## References

- [https://www.acn.gov.it/portale/w/rilevate-vulnerabilita-in-prodotti-compugroup-medical](https://www.acn.gov.it/portale/w/rilevate-vulnerabilita-in-prodotti-compugroup-medical)
- [https://www.cgm.com/ita_it/magazine/articles/comunicati-stampa/piu-sicurezza-per-farmacie-studi-medici-e-pazienti-cgm-italia-risolve-potenziali-vulnerabilita-software-insieme-a-csirt-italia.html](https://www.cgm.com/ita_it/magazine/articles/comunicati-stampa/piu-sicurezza-per-farmacie-studi-medici-e-pazienti-cgm-italia-risolve-potenziali-vulnerabilita-software-insieme-a-csirt-italia.html)