CVE-2025-54304 · Severity: critical · CVSS 9.8 · Published 2025-12-04

An issue was discovered on Thermo Fisher Ion Torrent OneTouch 2 INS1005527 devices. When they are powered on, an X11 display server is started. The display server listens on all network interfaces and is accessible over port 6000. The X11 access control list, by default, allows connections from 127.0.0.1 and 192.168.2.15. If a device is powered on and later connected to a network with DHCP, the device may not be assigned the 192.168.2.15 IP address, leaving the display server accessible by other devices on the network. The exposed X11 display server can then be used to gain root privileges and the ability to execute code remotely by interacting with matchbox-desktop and spawning a terminal. NOTE: This vulnerability only affects products that are no longer supported by the maintainer.

Vendors: [Thermofisher](https://junglewise.ai/threats/vendors/thermofisher).

## Quick answers

**Is CVE-2025-54304 exploited in the wild?** No. Junglewise Threat Intelligence has no report of CVE-2025-54304 being exploited in the wild.

**How severe is CVE-2025-54304?** Critical severity, with a CVSS score of 9.8, published 4 December 2025.

**Which products and versions are affected?** Thermofisher Ion Torrent Onetouch 2, Thermofisher Ion Torrent Onetouch 2 Firmware. The advisory does not name versions.

**Is there a fix for CVE-2025-54304?** No fixed version is recorded yet. Check the vendor's advisory in the references below. If you run it, Junglewise drafts a mitigation that fits your setup and applies it once you approve, with senior security engineers behind it.

**Am I affected by CVE-2025-54304?** Check whether you run Thermofisher Ion Torrent Onetouch 2 or Thermofisher Ion Torrent Onetouch 2 Firmware. Junglewise does that check for you around the clock: connect your code, cloud and domains, and it matches new vulnerabilities like this one against what you actually run and tells you when one reaches you.

## Affected products

- Thermofisher Ion Torrent Onetouch 2
- Thermofisher Ion Torrent Onetouch 2 Firmware