CVE-2025-40936 · Severity: high · CVSS 7.8 · Published 2025-11-17

Multiple Siemens engineering and simulation software products are affected by a vulnerability in how they process IGS design files. These tools are used by engineers to create 3D models and perform complex system simulations. If an attacker tricks a user into opening a specially crafted malicious file, they could crash the software or potentially take control of the user's computer to steal data or disrupt operations.

Technologies: [Siemens Simcenter Femap](https://junglewise.ai/threats/technologies/simcenter-femap), [Siemens Solid Edge](https://junglewise.ai/threats/technologies/solid-edge). Vendors: [Siemens](https://junglewise.ai/threats/vendors/siemens).

## Quick answers

**Is CVE-2025-40936 exploited in the wild?** No. Junglewise Threat Intelligence has no report of CVE-2025-40936 being exploited in the wild.

**How severe is CVE-2025-40936?** High severity, with a CVSS score of 7.8, published 17 November 2025.

**Which products and versions are affected?** Siemens Parasolid Translator Component < V29.0.258; Siemens Simcenter Femap < V2512.0003; Siemens Solid Edge < V226.00 Update 03.

**Is there a fix for CVE-2025-40936?** A patch was published on 2025-11-17: PS/IGES Parasolid Translator Component V29.0.258 released Junglewise finds every place you run it, drafts the upgrade and applies it once you approve.

**How is CVE-2025-40936 attacked?** It is attacked with local access, in a software library.

**Am I affected by CVE-2025-40936?** Check whether you run Siemens Parasolid Translator Component, Siemens Simcenter Femap or Siemens Solid Edge at an affected version. Junglewise does that check for you around the clock: connect your code, cloud and domains, and it matches new vulnerabilities like this one against what you actually run and tells you when one reaches you.

## Technical details

An out-of-bounds read vulnerability (CWE-125) exists in the PS/IGES Parasolid Translator Component, which is utilized by Siemens Simcenter Femap and Solid Edge. The flaw is triggered during the parsing of specially crafted IGS (Initial Graphics Exchange Specification) files. An attacker can exploit this by providing a malicious file to a user; upon opening, the application may read beyond allocated memory buffers. This can result in a denial-of-service (crash) or arbitrary code execution in the context of the current process. Siemens has released updates for the translator component and the integrated software suites to address this issue.

## Affected products

- Siemens PS/IGES Parasolid Translator Component < V29.0.258
- Siemens Simcenter Femap < V2512.0003
- Siemens Solid Edge < V226.00 Update 03

## Timeline

- 2025-11-17: disclosed: Initial disclosure for PS/IGES Parasolid Translator Component
- 2025-11-17: patched: PS/IGES Parasolid Translator Component V29.0.258 released
- 2026-02-10: advisory: Advisory updated to include Solid Edge impact
- 2026-06-09: advisory: Advisory updated to include Simcenter Femap impact

## References

- [https://cert-portal.siemens.com/productcert/html/ssa-241605.html](https://cert-portal.siemens.com/productcert/html/ssa-241605.html)
- [https://cert-portal.siemens.com/productcert/html/ssa-445819.html](https://cert-portal.siemens.com/productcert/html/ssa-445819.html)
- [https://cert-portal.siemens.com/productcert/html/ssa-870926.html](https://cert-portal.siemens.com/productcert/html/ssa-870926.html)

## Related threats

- [Siemens Simcenter Femap out-of-bounds read in BMP parsing](https://junglewise.ai/threats/cve-2026-59701-siemens-simcenter-femap-out-of-bounds-read-in-bmp-parsing)
- [Siemens Simcenter Femap out-of-bounds read in BMP parsing](https://junglewise.ai/threats/cve-2026-59700-siemens-simcenter-femap-out-of-bounds-read-in-bmp-parsing)
- [Siemens Simcenter stack overflow in argument parsing](https://junglewise.ai/threats/cve-2026-59086-siemens-simcenter-stack-overflow-in-argument-parsing)
- [Siemens Simcenter Femap heap overflow in Datakit library](https://junglewise.ai/threats/cve-2025-12659-siemens-simcenter-femap-heap-overflow-in-datakit-library)
- [Siemens Solid Edge uninitialized pointer access in PAR file parsing](https://junglewise.ai/threats/cve-2026-44411-siemens-solid-edge-uninitialized-pointer-access-in-par-file)